ASHRAE 110-2016 Certified

Independently Tested ASHRAE 110 Fume Hoods Built to Protect, Not Just to Pass

Metal chemical fume hoods with documented leakage of ≤ 0.05 ppm at 0.5 m/s face velocity. Fully customizable lining, worktop, and base cabinet — engineered for university, hospital, and research labs.

  • ASHRAE 110-2016 tested & certified, leakage ≤ 0.05 ppm
  • Cold-rolled, galvanized, or stainless-steel casing
  • Independent structural frame for heavier equipment loads
  • 3 widths (1200 / 1500 / 1800 mm), 6+ worktop materials
Request a Free Quote →
ASHRAE 110 certified chemical fume hood, YMEN series
✔ ASHRAE 110 Compliant ✔ Metal Casing, Not PP ✔ Fully Customizable ✔ OEM / Bulk Orders Welcome

Most Fume Hoods Leave Safety Gaps.
This One Doesn't.

Lab safety officers and procurement teams run into the same recurring issues. Here's how our ASHRAE 110 fume hoods solve each one.

PP Hoods Fail Under Heat

Polypropylene hoods can warp and degrade in high-temperature environments. Metal casing stays structurally stable where PP cannot.

Unverified Leakage Claims

Many hoods claim "safe" with no proof behind it. Our fume hoods are independently tested to ASHRAE 110-2016, with leakage documented at ≤ 0.05 ppm.

One-Size-Fits-All Doesn't Fit Your Lab

Different labs need different worktop chemistries, liner materials, and base cabinets. Our fume hoods are configurable across every major dimension.

Weak Frames Under Heavy Equipment

Most hoods carry load through the cabinet shell alone. Ours uses an independent structural frame beneath the hood for stronger load capacity and long-term rigidity.

Designed Around the Chemistry, Not Around the Price Point

Every construction detail on our ASHRAE 110 fume hoods has a functional reason behind it.

🛡️

ASHRAE 110-2016 Compliant

Leakage ≤ 0.05 ppm at 0.5 m/s face velocity — tested, not estimated.

🏗️

Independent Structural Frame

A hood-independent frame delivers stronger load capacity and long-term dimensional stability.

🌊

Arc-Design Air Foil

Curved cold-rolled-steel airfoil guides airflow smoothly into the hood, reducing turbulence at the sash face.

💧

Marine-Edge Worktop

A raised perimeter edge keeps chemical spills and water from reaching the floor.

🔩

160 mm Aluminum Handle

Heavy-duty lab-grade aluminum handle profile for firm, ergonomic sash control.

📱

TIFF Touch-Screen Panel

English-language TIFF touch-screen control panel for intuitive monitoring at a glance.

💡

900+ Lux LED Lighting

Dual 18W LED lamps deliver over 900 Lux on the worktop surface for clear visibility.

⚙️

Tempered Glass Sash

1.5 mm aluminum-framed sash with 5 mm tempered glass, max opening height 720 mm.

Choose Your Width. The Build Quality Doesn't Change.

Three standard widths — 1200 / 1500 / 1800 mm — same construction standard, scaled air capacity.

Note: Casing is 1.2 mm cold-rolled steel with epoxy coating plus 5 mm compact-board lining on all three models. Baffle plate is 5 mm compact sheet. Air foil is arc-design cold-rolled steel with epoxy coating.
Specification YMEN1 YMEN2 YMEN3
External Size (mm) W 1200 × D 900 × H 2350 W 1500 × D 900 × H 2350 W 1800 × D 900 × H 2350
Internal Size (mm) W 920 × D 670 × H 1030 / 1240 W 1220 × D 670 × H 1030 / 1240 W 1520 × D 670 × H 1030 / 1240
Top Outlet Diameter Ø 230 mm Ø 230 mm Ø 300 mm
Air Capacity (CMH) 900 – 1100 1100 – 1300 1500 – 1700
Pressure Drop 70 Pa 80 Pa 90 Pa
Sash Opening (max) 720 mm height
Sash Construction 1.5 mm aluminum alloy frame + 5 mm tempered glass
Standard Worktop 12.7 mm black phenolic resin with marine edge (other options available)

Standard Accessories & Fixtures

💡
Lighting

2 × 18W LED lamp, >900 Lux on worktop

💧
Water Supply

1 × single-way brass water tap + 1 × PP cap

🔌
Electrical

3 × waterproof 3-pin sockets with covers

📟
Control Panel

1 × English TIFF touch-screen control panel

Configure It for Your Application

Lining material, casing, base cabinet, and worktop are all selectable, so your procurement spec doesn't need to compromise.

🧱

Hood Lining Options

HPL (high-pressure laminate), stainless steel, or ceramic — selected by chemical resistance requirement.

🏭

Cabinet Casing Material

Cold-rolled steel, galvanized steel, or stainless steel — matched to environment and corrosion exposure.

🗄️

Base Cabinet Options

Metal base cabinet, PP base cabinet, or flammable-storage safety cabinet — choose by chemical storage class.

Worktop Material Selection

Phenolic Resin
Most Popular

Thickness: 12.7 / 16 / 19 / 25 mm or custom
Colors: Black, Grey, White or custom
Best for: University, hospital, testing lab

Epoxy Resin
Chemical Resistant

Thickness: 15 / 16 / 19 / 20 / 25 mm
Colors: Black, Grey, White, Blue
Best for: University, hospital

Ceramic
High Temp & Acid

Thickness: 20 mm
Colors: Black, Blue
Best for: Pharmaceutical, research lab

Trespa
Impact Resistant

Thickness: 13 / 16 / 20 mm
Colors: Black
Best for: Hospital, research lab

Stainless Steel
Cleanroom Grade

Thickness: 25 mm
Color: Brushed
Best for: Microbiology lab

Marble
Balance Tables

Thickness: 40 mm
Color: Black
Best for: Balance / weighing tables

Frequently Asked Questions

Answers our lab furniture team gets most often about ASHRAE 110 fume hoods.

What does ASHRAE 110-2016 certification actually mean?

ASHRAE 110-2016 is the standard test method used to measure how well a fume hood contains hazardous fumes at the face opening. Our fume hoods are independently tested against this standard, with documented leakage of ≤ 0.05 ppm at a 0.5 m/s face velocity — well within the containment threshold labs rely on for staff safety.

Why choose a metal fume hood over a polypropylene (PP) one?

Metal casing holds its shape and structural integrity in high-temperature or heavy-use environments where PP hoods can soften, warp, or degrade over time. Metal fume hoods are also better suited to carrying heavier benchtop equipment thanks to the independent structural frame.

What sizes are available?

Three standard widths are available: YMEN1 (1200 mm), YMEN2 (1500 mm), and YMEN3 (1800 mm). All three share the same 900 mm depth and 2350 mm height, so you can size to your lab layout without sacrificing build quality.

Can the worktop and lining be customized?

Yes. Worktops are available in phenolic resin, epoxy resin, ceramic, Trespa, stainless steel, or marble, and hood lining can be specified in HPL, stainless steel, or ceramic depending on the chemicals you're working with. Base cabinets can be metal, PP, or a flammable-storage safety cabinet.

What is included with each fume hood?

Every unit ships with dual 18W LED lighting (over 900 Lux on the worktop), a single-way brass water tap with PP cap, three waterproof 3-pin sockets, and an English-language TIFF touch-screen control panel.

Do you support OEM or bulk orders?

Yes, OEM branding and bulk/project quantities are welcome. Share your width, worktop, lining, and base cabinet preferences and our team will prepare a formal quotation within 24 hours.

Ready to Specify the Right Fume Hood?

Tell us your width, worktop, lining, and base cabinet preference — we'll prepare a formal quotation within 24 hours.

Request a Free Quote →
Get Instant Quote Now

Contact Us